Manchester skyline

PART L COMPLIANCE

Part L Air Leakage
Testing of Buildings

Air pressure testing evaluates a building's air tightness — identifying uncontrolled leakage through gaps, holes or cracks that impact energy efficiency and increase running costs.

24 Hour Delivery

Report emailed within 24 hours

Nationwide Coverage

Call, text or order online

Trusted by Solicitors

Relied on across the industry

HOW IT'S DONE

The Testing Process

Once you or your architects provide complete drawings — floor plans, sections, elevations and a site plan — we use your design stage SAP or SBEM air tightness target as the benchmark for testing.

Fan Installation

A large fan is temporarily fitted, usually in a doorway, ready to begin the test.

Sealing Openings

Openings to the property are temporarily sealed before the fan is switched on.

Pressure Measurement

Air pressure is gradually increased and decreased, recording the differential at each step.

Leakage Calculation

Airflow at 50 Pa is divided by the building envelope area to give the leakage rate in m³/h.m².

WHY DO I NEED IT

Who Needs This Test

New Builds

Mandatory for new residential and commercial constructions since 2006 (2010 in Scotland).

Extended Commercial Properties

Larger commercial extensions typically require testing to meet Part L standards.

Residential Extensions & Conversions

Not always legally required, but often tested for peace of mind and energy performance.

Reviewing building compliance documents

ADDRESSING FAILURE

Common Causes of a Failed Test

Insufficient sealing around windows and doors

Gaps and spaces behind fitted units

Cracks and gaps around electrical sockets

Poorly sealed junctions at the wall-floor connection

Unsealed spaces around pipework and service penetrations

GET A QUOTE

FURTHER DIAGNOSTICS

Pinpointing Problem Areas

Smoke Testing

We fill the building with smoke and pressurise the space, giving a visible indication of problem areas as smoke escapes through openings. Smoke pencils are used for more targeted checks.

Depressurisation

The whole building is pressurised, forcing air out through gaps and cracks. As pressure is reduced, draughts reveal exactly where air is escaping.

Thermography

Infrared cameras detect the hottest and coldest spots in the building, pinpointing insulation and air leakage issues that aren't visible to the eye.

0%

Potential Heat Loss Prevented

0hrs

Typical Test Duration

0Pa

Standard Test Pressure

0hrs

Report Turnaround

FAQS

Air Testing Questions Answered

It's an assessment of a building's air tightness — also called air permeability or leakage rate — identifying uncontrolled air leakage through gaps, holes or cracks in the building fabric.

Yes, for new residential and commercial constructions in England, Wales and Northern Ireland since 2006, and in Scotland since 2010, to meet design stage SAP or SBEM air permeability targets.

Complete drawings including floor plans, sections, elevations and a site plan, along with the air tightness target from your design stage SAP or SBEM calculations.

Generally no more than two hours, depending on property size and preparation. It should be carried out towards the end of the project.

We offer consultation, on-site training and further diagnostic testing — including smoke testing, depressurisation and thermography — to pinpoint and resolve the problem areas.

Book Your Air Pressure Test Today

Nationwide coverage, fast turnaround, and reports trusted by solicitors and contractors across the UK.

BOOK AN APPOINTMENT